procedure NotifyWait(iId : Integer; iSeconds : Integer);

Class IHL7Connect

By default, Hl7Connect will wait the the configured timeout for a response from the interface, not knowing the status. Set the timeout too short, and HL7Connect will abandon the message/document before you've processed it, it processing takes too long. Set the timeout too long, and HL7Connect will take ages to give up on the client when the client is not available. One way to resolve this is for to notify Hl7Connect with an estimate of how long processing will take using this method

The instance identifier is the parameter of the SendMessage or SendDocument method.

HL7Connect will wait the specified number of seconds from the time *it started waiting*.


© Kestral Computing P/L 2000 - 2003. HL7Connect v2.00-063 generated on 30-Nov 2015.